91- 33 - 4005 1347 / 4005 0941
 
Keep Touch with Us :
Agilent Technologies (USA) Chromatopak Analytical Instrumentations (India) Pvt. Ltd.  Pall Corporation (USA)  Techscience Services Pvt. Ltd. (ndia) Parker Hannifin India Pvt. Ltd. Thermo Fisher Scientific Hwashin Technology Company Aaral Tech Pvt. Ltd. Technos Instruments
 
Home About Us Products News & Updates Contact Us Clients Enquiry
 
 
General Separations Capillary Columns
 

General Separation Technologies, USA offers a wide selection of high quality GsBP series of GC Capillary Columns.

Features:

  • Consistent high performance w.r.t inertness and column bleed
  • Generates high efficiency separations
  • Stringent Q.C methods adopted
  • Wide range of polysiloxane based stationary phases
  • Wide selection of PLOT columns

GsBP -1, 100% poly (dimethylsiloxane)

  • 100% bonded and crosslinked dimethylpolysiloxane
  • Non-polar, equivalent to USP phase G2
  • Solvent rinseable and high temperature limit
  • Wide range of coloumn dimensions and stationary phase film thickness
  • Low column bleed, inert surface and high efficiency
  • Most popular for general applications
  • Similar to : DB-1,BP-1, CP-Sil5CB, RTX-1, ZB-1, AT-1, HP-1, SPB-1

GsBP-1 MS, 100% poly(dimethylsiloxane)

  • Identical selectivity to GsBP-1 but with much lower column bleed
  • Ideal for GC-MS analysis and first choice for new method development
  • Similar to DB-1MS,BP-1, CP-Sil5CB Low bleed, RTX-1MS

GsBP -5, 5% phenyl, 95% dimethyl polysiloxane

  • 5% phenyl, 95% dimethyl polysiloxane bonded and crosslinked
  • Non-polar, equivalent to USP phase G27
  • Solvent rinseable and high temperature limit
  • Wide range of column dimensions and stationary phase film thickness
  • Low column bleed, inert, neutral surface with high efficiency
  • Most popular for general applications
  • Similar to DB-5,BP-5, CP-Sil8CB, RTX-5, ZB-5, AT-5, HP-5, SPB-5

GsBP-5 MS, 5% phenyl, 95% dimethyl polysiloxane

  • Identical selectivity to GsBP-5 but which much lower column bleed
  • Best surface inertness for wide range of compounds
  • Ideal for GC-MS analysis or for new method development
  • Similar to : to DB-5MS,BPX-5, CP-Sil8CB Low bleed, RTX-5MS, AT-5MS

GsBP- 35 MS, 35% phenyl, 65% dimethyl polysiloxane

  • Bonded and crosslinked 35% phenyl , 65% dimethylsiloxane phase
  • Equivalent to USP phase G-42
  • Inert to many active compounds
  • Low column bleed to improve sensitivity and quantitation
  • Applications: Aroclors, PCBs, amines, pesticides, pharmaceutical molecules
  • Good confirmation analysis of active compounds on GsBP-5MS columns
  • Similar to : DB-35MS, BPX-35

GsBP -50 +MS, 50% phenyl, 50% dimethyl polysiloxane

  • Boonded and crosslinked 50% phenyl, 50% dimethyl polysiloxane
  • Equivalent to USP phase G3
  • Inert to many active compounds
  • Low column bleed to improve sensitivity and quantitation
  • Applications: common drug screens, phenols, PAHs, free steroids, pesticides, herbicides.
  • Good confirmation of the analysis of active compounds on GsBP-5MS or GsBP-35MS columns.
  • Similar to : DB-17MS, BPX- 50, RTX-50, SPB-50, AT-50

GsBP-1701, 14% cyanopropylphenyl, 86% dimethyl polysiloxane

  • Bonded crosslinked cyanopropylphenyl, 86% dimethyl polysiloxane phase
  • Low to mid polarity
  • Equivalent to USP phase G-46
  • Inert to many active compounds
  • Applications: pesticides, herbicides, halogenates
  • Good confirmation of analysis of active compounds on GsBP-5MS or GsBP-50+ MS columns
  • Similar to DB -1701, BP- 10, CP Sil9CB, SPB-1701, ZB-1701

GsBP-1301, 6% cyanopropylphenyl, 94% dimethyl polysiloxane

  • Bonded and crosslinked 6% cyanopropylphenyl, 94% dimethyl polysiloxane phase
  • Equivalent to USP phase G 43, low to mid polarity
  • Inert to many active compounds
  • Applications: pesticides, herbicides, halogenates.
  • Good confirmation of the analysis of active compounds on GsBP- 5MS or GsBP -35MS columns
  • Similar to DB – 1301, RTX – 1301

GsBP- 624 proprietary polysiloxane stationary phase

  • Bonded and crosslinked specially designed stationary phase for EPA methods
  • Low Polarity
  • Equivalent to USP phase G43 6% cyanopropylphenyl, 94% methyl polysiloxane
  • Inert to many active compounds
  • Applications: EPA methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, 8260
  • Similar to : DB-624, BP-624, RTX-624, ZB-624

GsBP INOWAX, Bonded polyethylene glycol

  • Bonded and crosslinked PEG
  • Solvent rinseable
  • Highest temperature limits of bonded PEG phases
  • Polar phase, equivalent to USP phase G 16
  • Wide applications of polar solvent analysis in food, pharma, cosmetics, petrochemical industries.
  • Similar to : DB-WAX, HP-Innowax, BP-20, CP-WAX52CB, Supelcowax-10, Stabilwax, ZB-WAX

GsBP- CarboWax 20M polyethylene glycol

  • PEG, MW 20,000
  • Non-bonded non- crosslinked phase
  • Polar phase equivalent to USP phase G16
  • Replacement of packed columns with CArbowax 20M modified

GsBP – FFAP, bonded acid modified PEG

  • Nitrorerepthalic acid modified PEG
  • Bonded and crosslinked
  • Non-alcohol/aqueous solvent rinseable
  • High temperature limit
  • Polar phase, equivalent to USP phase G35
  • Designed for the analysis of  volatile fatty acids and phenols
  • Similar to : DB-FFAP, Stabilwax-DA, CP-Wax58CB

GsBP PONA 100% dimethylpolysiloxane

  • Bonded and crosslinked
  • High resolution Analysis of hydrocarbons
  • Specifically configured for analysis of Petroleum processed products(PONA, PIANO etc)
  • Similar to HP-PONA, Petrocol DH, DB-Petro 100

GsBP- 502.2, proprietary phase

  • Bonded and cross linked
  • Excellent peak shapes for Volatile Organic Compounds

GsBP-PLOT Al2 O3 “KCL”

  • Least selective Olefins (“polar”) aluminium oxide phase
  • Deactivated with KCL
  • Good baseline separation of most C1 to C10 hydrocarbons
  • Olefins may co-elute with corresponding paraffin over C5
  • Minimum surface adsorption of dienes and halocarbons
  • ASTM recommended phase
  • Preferred choice for hydrocarbon separation
  • Similar to : GS-Alumina KCL, CP-Al2O3/KCL, RT-AluminaPLOT

GsBP-PLOT Al2 O3  “S”

  • Good selective Olefins (mid “polar”) aluminium oxide phase
  • Deactivated with Na2SO4 salt
  • Excellent baseline separation of C1 to C10 hydrocarbons, excellent of C3, C4 misomer baseline separation
  • Less accurate quantitations of dienes and halocarbons
  • ASTM recommended phase
  • Preferred choice for hydrocarbon separation
  • Similar to : HP-PLOT Al2O3’S’, CP-Al2O3 PLOT Na2SO4

GsBP-PLOT Al2O3  “M”

  • Strong selective Olefins (most “polar”) aluminium oxide phase
  • Deactivated with Na2MoO4 salt
  • Mostly baseline separation of C1 to C10 hydrocarbons, good baseline separation of cyclopropane from propylene
  • Accurate quantitations of dienes and halocarbons
  • ASTM recommended phase
  • Preferred choice for hydrocarbon separation
  • Similar to : HP-PLOT Al2O3M

GsBP-PLOT MoleSieve, molecular sieves, 5A type

  • Molecular Sieve, Zeolite, 5A
  • Thin and thick coatings for push limit separations, e.g. Ar/O2 separation at 35°C, O2 /N2 within 15sec
  • Truly immobilize coating and smooth baseline workable for valve switching
  • Preferred column to analyze fixed gases from hydrocarbon streams
  • Elution order, H2 , He, Ne, O2 , N2, CH4 , CO
  • Regeneration of performance from water/CO2 adsorptions at 250°C for 3hr
  • ASTM recommended phase
  • Noble gas, air from methane, fuel gas, etc
  • Often used with other PLOT columns for fixed gas separation from sample matrix
  • Similar to : HP-PLOT MoleSieve., CP-Moleseive 5A

GsBP-PLOT GasPro, proprietary porous silica coating

  • Proprietary Silica base phase
  • Very inert to wide range of gases including sulfur gases and Freons, symmetric peak shapes
  • Truly immobilized coating and smooth baseline workable for valve switching
  • Preferred column to analyze sulfur gases from hydrocarbon streams and air
  • Separation of CO and CO2
  • Minimum effect of water on retention time
  • Regeneration of performance from water adsorptions at 250C for 3hr
  • ASTM recommended phase
  • GC-MS applicable
  • Similar to : GS-Gas Pro, CP-Silica PLOT

GsBP-PLOT Q, porous divinylbenzene polymer

  • Divinylbenzene polymer particle, nonpolar, close to traditional PoraPak Q
  • Truly immobilized coating and smooth baseline workable for valve switching and liquid sample introduction at low temperatures
  • Highest temperature limit, upto 280/300°C
  • Baseline separation of Air, CO2 , water, sulfur gases, hydrogen chlorine, ammonia/light amines from hydrocarbons such as refinery stream, natural gas, and engine exhaust
  • Excellent separation of C1 to C3 isomers, good separations of C3 to C12, halocarbons
  • Excellent inertness and stability of water/alcohol sample, a good secondary choice of wax column for alcohol analysis
  • Excellent tolerance to strong acid/base sample without affecting retention time
  • Good anti-oxidation at 280°C and fast regeneration of performance
  • Observed slight sulfur gas, hydrogen chlorine, and amine absorption
  • Water peak is tailing, but no effect on retention
  • Good choice for analyzing low level solvent residues from wide samples, such as headspace, aqueous, or Organic solutions
  • Preferred column for residue analysis in petroleum industry, pharmaceutical, environmental, chemical weapon detection
  • Preferred column to analyze polar compounds including oxygenates from hydrocarbon streams: natural gas, refinery Gas, dienes, ethylene, propylene
  • Similar to : HP-PLOT Q, CP-PoraPLOT Q, RT-Q PLOT

GsBP-PLOT U, porous ethylene glycol dimethacrylate copolymer

  • Divinylbenzene and Ethylene glycol dimethacrylate copolymer particle, polar
  • Truly immobilized coating and smooth baseline workable for valve switching and liquid sample introduction at low temperatures
  • Improved separation and selectivity of Air, CO2 , water, sulfur gases, hydrogen chlorine, ammonia/light amines  from hydrocarbons
  • Symmetric water peak shape, water elute after C3
  • Excellent separation of C1 to C3 isomers, good separations of C3 to C12, halocarbons
  • Excellent inertness and stability of water/alcohol sample, a good secondary choice of wax column for alcohol analysis
  • Excellent tolerance to strong acid/base sample without affecting retention time
  • Observed slight sulfur gas, hydrogen chlorine, and amine absorption
  • Good choice for analyzing low level solvent residues from wide samples, such as headspace, aqueous, or organic solutions
  • Preferred column for residue analysis in petroleum industry, pharmaceutical, environmental, chemical weapon detection
  • Preferred column to analyze polar compounds including oxygenates from hydrocarbon streams: natural gas, refinery gas, Dienes, ethylene, propylene
  • Similar to : PoraPLOT U, RT-U PLOT

GsBP-Blood Alcohol Column, proprietary PLOT phase

  • Proprietary PLOT phase
  • Reliable blood alcohol analysis
  • Tolerance of direct sample injection
  • Excellent confirmation column against other blood alcohol columns using t-butanol as internal standard
  • Similar to : DB-ALC1, RTX-BAC1
 
 
 
 
 
Home   I   About Us   I   Products   I   News & Updates    I   Contact Us   I   Clients  I   Enquiry
 
Site Powered By : www.calcuttayellowpages.com