          General Separation Technologies, USA offers a wide selection of high quality GsBP series of GC Capillary Columns. 
            
          Features: 
          
            - Consistent high performance w.r.t inertness and column bleed
 
            - Generates high efficiency separations
 
            - Stringent Q.C methods adopted
 
            - Wide range of polysiloxane based stationary phases
 
            - Wide selection of PLOT columns
 
           
          GsBP -1, 100% poly (dimethylsiloxane)
          
            - 100% bonded and crosslinked dimethylpolysiloxane
 
            - Non-polar, equivalent to USP phase G2
 
            - Solvent rinseable and high temperature limit
 
            - Wide range of coloumn dimensions and stationary phase film thickness
 
            - Low column bleed, inert surface and high efficiency
 
            - Most popular for general applications
 
            - Similar to : DB-1,BP-1, CP-Sil5CB, RTX-1, ZB-1, AT-1, HP-1, SPB-1
 
           
          GsBP-1 MS, 100% poly(dimethylsiloxane)
          
            - Identical selectivity to GsBP-1 but with much lower column bleed
 
            - Ideal for GC-MS analysis and first choice for new method development
 
            - Similar to DB-1MS,BP-1, CP-Sil5CB Low bleed, RTX-1MS
 
           
          GsBP -5, 5% phenyl, 95% dimethyl polysiloxane
          
            - 5% phenyl, 95% dimethyl polysiloxane bonded and crosslinked
 
            - Non-polar, equivalent to USP phase G27
 
            - Solvent rinseable and high temperature limit
 
            - Wide range of column dimensions and stationary phase film thickness
 
            - Low column bleed, inert, neutral surface with high efficiency
 
            - Most popular for general applications
 
            - Similar to DB-5,BP-5, CP-Sil8CB, RTX-5, ZB-5, AT-5, HP-5, SPB-5
 
           
          GsBP-5 MS, 5% phenyl, 95% dimethyl polysiloxane
          
            - Identical selectivity to GsBP-5 but which much lower column bleed
 
            - Best surface inertness for wide range of compounds
 
            - Ideal for GC-MS analysis or for new method development
 
            - Similar to : to DB-5MS,BPX-5, CP-Sil8CB Low bleed, RTX-5MS, AT-5MS
 
           
          GsBP- 35 MS, 35% phenyl, 65% dimethyl polysiloxane
          
            - Bonded and crosslinked 35% phenyl , 65% dimethylsiloxane phase
 
            - Equivalent to USP phase G-42
 
            - Inert to many active compounds
 
            - Low column bleed to improve sensitivity and quantitation
 
            - Applications: Aroclors, PCBs, amines, pesticides, pharmaceutical molecules
 
            - Good confirmation analysis of active compounds on GsBP-5MS columns
 
            - Similar to : DB-35MS, BPX-35
 
           
          GsBP -50 +MS, 50% phenyl, 50% dimethyl polysiloxane
          
            - Boonded and crosslinked 50% phenyl, 50% dimethyl polysiloxane
 
            - Equivalent to USP phase G3
 
            - Inert to many active compounds
 
            - Low column bleed to improve sensitivity and quantitation
 
            - Applications: common drug screens, phenols, PAHs, free steroids, pesticides, herbicides.
 
            - Good confirmation of the analysis of active compounds on GsBP-5MS or GsBP-35MS columns.
 
            - Similar to : DB-17MS, BPX- 50, RTX-50, SPB-50, AT-50
 
           
          GsBP-1701, 14% cyanopropylphenyl, 86% dimethyl polysiloxane
          
            - Bonded crosslinked cyanopropylphenyl, 86% dimethyl polysiloxane phase
 
            - Low to mid polarity
 
            - Equivalent to USP phase G-46
 
            - Inert to many active compounds
 
            - Applications: pesticides, herbicides, halogenates
 
            - Good confirmation of analysis of active compounds on GsBP-5MS or GsBP-50+ MS columns
 
            - Similar to DB -1701, BP- 10, CP Sil9CB, SPB-1701, ZB-1701
 
           
          GsBP-1301, 6% cyanopropylphenyl, 94% dimethyl polysiloxane
          
            - Bonded and crosslinked 6% cyanopropylphenyl, 94% dimethyl polysiloxane phase
 
            - Equivalent to USP phase G 43, low to mid polarity
 
            - Inert to many active compounds
 
            - Applications: pesticides, herbicides, halogenates.
 
            - Good confirmation of the analysis of active compounds on GsBP- 5MS or GsBP -35MS columns
 
            - Similar to DB – 1301, RTX – 1301
 
           
          GsBP- 624 proprietary polysiloxane stationary phase
          
            - Bonded and crosslinked specially designed stationary phase for EPA methods
 
            - Low Polarity
 
            - Equivalent to USP phase G43 6% cyanopropylphenyl, 94% methyl polysiloxane
 
            - Inert to many active compounds
 
            - Applications: EPA methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, 8260
 
            - Similar to : DB-624, BP-624, RTX-624, ZB-624
 
           
          GsBP INOWAX, Bonded polyethylene glycol
          
            - Bonded and crosslinked PEG
 
            - Solvent rinseable
 
            - Highest temperature limits of bonded PEG phases
 
            - Polar phase, equivalent to USP phase G 16
 
            - Wide applications of polar solvent analysis in food, pharma, cosmetics, petrochemical industries.
 
            - Similar to : DB-WAX, HP-Innowax, BP-20, CP-WAX52CB, Supelcowax-10, Stabilwax, ZB-WAX
 
           
          GsBP- CarboWax 20M polyethylene glycol
          
            - PEG, MW 20,000
 
            - Non-bonded non- crosslinked phase
 
            - Polar phase equivalent to USP phase G16
 
            - Replacement of packed columns with CArbowax 20M modified
 
           
          GsBP – FFAP, bonded acid modified PEG
          
            - Nitrorerepthalic acid modified PEG
 
            - Bonded and crosslinked
 
            - Non-alcohol/aqueous solvent rinseable
 
            - High temperature limit
 
            - Polar phase, equivalent to USP phase G35
 
            - Designed for the analysis of  volatile fatty acids and phenols
 
            - Similar to : DB-FFAP, Stabilwax-DA, CP-Wax58CB
 
           
          GsBP PONA 100% dimethylpolysiloxane
          
            - Bonded and crosslinked
 
            - High resolution Analysis of hydrocarbons
 
            - Specifically configured for analysis of Petroleum processed products(PONA, PIANO etc)
 
            - Similar to HP-PONA, Petrocol DH, DB-Petro 100
 
           
          GsBP- 502.2, proprietary phase
          
            - Bonded and cross linked
 
            - Excellent peak shapes for Volatile Organic Compounds
 
           
          GsBP-PLOT Al2 O3 “KCL”
          
            - Least selective Olefins (“polar”) aluminium oxide phase
 
            - Deactivated with KCL
 
            - Good baseline separation of most C1 to C10 hydrocarbons
 
            - Olefins may co-elute with corresponding paraffin over C5
 
            - Minimum surface adsorption of dienes and halocarbons
 
            - ASTM recommended phase
 
            - Preferred choice for hydrocarbon separation
 
            - Similar to : GS-Alumina KCL, CP-Al2O3/KCL, RT-AluminaPLOT
 
           
          GsBP-PLOT Al2 O3  “S”
          
            - Good selective Olefins (mid “polar”) aluminium oxide phase
 
            - Deactivated with Na2SO4 salt
 
            - Excellent baseline separation of C1 to C10 hydrocarbons, excellent of C3, C4 misomer baseline separation
 
            - Less accurate quantitations of dienes and halocarbons
 
            - ASTM recommended phase
 
            - Preferred choice for hydrocarbon separation
 
            - Similar to : HP-PLOT Al2O3’S’, CP-Al2O3 PLOT Na2SO4
 
           
          GsBP-PLOT Al2O3  “M”
          
            - Strong selective Olefins (most “polar”) aluminium oxide phase
 
            - Deactivated with Na2MoO4 salt
 
            - Mostly baseline separation of C1 to C10 hydrocarbons, good baseline separation of cyclopropane from propylene
 
            - Accurate quantitations of dienes and halocarbons
 
            - ASTM recommended phase
 
            - Preferred choice for hydrocarbon separation
 
            - Similar to : HP-PLOT Al2O3M
 
           
          GsBP-PLOT MoleSieve, molecular sieves, 5A type
          
            - Molecular Sieve, Zeolite, 5A
 
            - Thin and thick coatings for push limit separations, e.g. Ar/O2 separation at 35°C, O2 /N2 within 15sec
 
            - Truly immobilize coating and smooth baseline workable for valve switching
 
            - Preferred column to analyze fixed gases from hydrocarbon streams
 
            - Elution order, H2 , He, Ne, O2 , N2, CH4 , CO
 
            - Regeneration of performance from water/CO2 adsorptions at 250°C for 3hr
 
            - ASTM recommended phase
 
            - Noble gas, air from methane, fuel gas, etc
 
            - Often used with other PLOT columns for fixed gas separation from sample matrix
 
            - Similar to : HP-PLOT MoleSieve., CP-Moleseive 5A
 
           
          GsBP-PLOT GasPro, proprietary porous silica coating
          
            - Proprietary Silica base phase
 
            - Very inert to wide range of gases including sulfur gases and Freons, symmetric peak shapes
 
            - Truly immobilized coating and smooth baseline workable for valve switching
 
            - Preferred column to analyze sulfur gases from hydrocarbon streams and air
 
            - Separation of CO and CO2
 
            - Minimum effect of water on retention time
 
            - Regeneration of performance from water adsorptions at 250C for 3hr
 
            - ASTM recommended phase
 
            - GC-MS applicable
 
            - Similar to : GS-Gas Pro, CP-Silica PLOT
 
           
          GsBP-PLOT Q, porous divinylbenzene polymer
          
            - Divinylbenzene polymer particle, nonpolar, close to traditional PoraPak Q
 
            - Truly immobilized coating and smooth baseline workable for valve switching and liquid sample introduction at low temperatures
 
            - Highest temperature limit, upto 280/300°C
 
            - Baseline separation of Air, CO2 , water, sulfur gases, hydrogen   chlorine, ammonia/light amines from hydrocarbons such as refinery   stream, natural gas, and engine exhaust
 
            - Excellent separation of C1 to C3 isomers, good separations of C3 to C12, halocarbons
 
            - Excellent inertness and stability of water/alcohol sample, a good secondary choice of wax column for alcohol analysis
 
            - Excellent tolerance to strong acid/base sample without affecting retention time
 
            - Good anti-oxidation at 280°C and fast regeneration of performance
 
            - Observed slight sulfur gas, hydrogen chlorine, and amine absorption
 
            - Water peak is tailing, but no effect on retention
 
            - Good choice for analyzing low level solvent residues from wide samples, such as headspace, aqueous, or Organic solutions
 
            - Preferred column for residue analysis in petroleum industry, pharmaceutical, environmental, chemical weapon detection
 
            - Preferred column to analyze polar compounds including oxygenates   from hydrocarbon streams: natural gas, refinery Gas, dienes, ethylene,   propylene
 
            - Similar to : HP-PLOT Q, CP-PoraPLOT Q, RT-Q PLOT
 
           
          GsBP-PLOT U, porous ethylene glycol dimethacrylate copolymer
          
            - Divinylbenzene and Ethylene glycol dimethacrylate copolymer particle, polar
 
            - Truly immobilized coating and smooth baseline workable for valve switching and liquid sample introduction at low temperatures
 
            - Improved separation and selectivity of Air, CO2 , water, sulfur   gases, hydrogen chlorine, ammonia/light amines  from hydrocarbons
 
            - Symmetric water peak shape, water elute after C3
 
            - Excellent separation of C1 to C3 isomers, good separations of C3 to C12, halocarbons
 
            - Excellent inertness and stability of water/alcohol sample, a good secondary choice of wax column for alcohol analysis
 
            - Excellent tolerance to strong acid/base sample without affecting retention time
 
            - Observed slight sulfur gas, hydrogen chlorine, and amine absorption
 
            - Good choice for analyzing low level solvent residues from wide samples, such as headspace, aqueous, or organic solutions
 
            - Preferred column for residue analysis in petroleum industry, pharmaceutical, environmental, chemical weapon detection
 
            - Preferred column to analyze polar compounds including oxygenates   from hydrocarbon streams: natural gas, refinery gas, Dienes, ethylene,   propylene
 
            - Similar to : PoraPLOT U, RT-U PLOT
 
           
          GsBP-Blood Alcohol Column, proprietary PLOT phase
          
            - Proprietary PLOT phase
 
            - Reliable blood alcohol analysis
 
            - Tolerance of direct sample injection
 
            - Excellent confirmation column against other blood alcohol columns using t-butanol as internal standard
 
            - Similar to : DB-ALC1, RTX-BAC1
 
                      |