A fan consists of                     a series of   radial blades/impellers attached to a central rotating                       hub. The rotating assembly of blades and hub comprises a fan                       assembly and it may or may not be enclosed in a housing.   Fans                     are driven by an electric motor to generate   airflow through                     a given system.
              
              • Impeller 
            The impellers of the Pasko fan are tested for   simulated aerodynamic                     loads, load deflection   characteristics and the strain at the                     shank. Pasko   Impellers usually have blades with cross-sections                       matching those of an aerofoil. As compared to curved sheet blades,                       aerofoil can apply greater force to the air, thereby   increasing                     maximum pressure and can maintain better   efficiency over a wider                     range of volumetric flow.   Also by increasing the thickness &                     curvature of   the inner sections, the blades can be made stiffer;                       this limits flutter and allows the impellers to run at higher                       speeds.
  
  
• Casing
            The casing encloses the impeller and motor   assembly completely.                     Pasko axial flow fan casings   are generally rolled and flanged                     from heavy-gauge   mild steel. Flameproof and increased-safety                     motors   are not normally placed outside the casing and can be                       connected directly to the terminal box in accordance with the                       requirements for the particular hazardous zone. 
            
  
  • Hub
            The design of Pasko fan impeller and hub is   based on the worst                     possible aerodynamic load and   centrifugal load scenario. The                     hub incorporates a   system for the adjustment of pitch angle,                     cleaning   or repair of the impellers.
              
              
• Fixings 
            All impellers are assembled together using   high-tensile, zinc-plated                     bolts and self- locking   nuts.
            
            • Balance 
            The balance of impeller assembly complete with   the hub is carefully                     checked to ensure   vibration-free running. Both the static &                       dynamic balance tests are carried out before testing the fan                       for its performance.
            
            
• Pitch Adjustment 
            The blades of Pasko axial-flow fans are often   attached to the                     hubs by a system which allows the   pitch angle to be set at any                     desired value on   assembly. This adjustment pitch feature enables                     the   fan to be supplied preset for exactly the volume flow required,                       eliminating the waste of power. 
            
            • Tip Clearance
            Pasko fan impellers are generally mounted on the   shaft extension                     of the driving system. This is   supported in a cylindrical casing                     surrounding the   impeller with the minimum practical running                       clearance; a typical value for this radial clearance is 0.25%                       of the impeller diameter.
            
            
• Fan Driving Systems
            The fan assembly could be mounted on a wide   range of driving                     systems to meet the desired range   of performances and applications.                     These includes the   following:
            
            • Direct-drive 
            In this case, the fan is directly mounted on the motor shaft                     inside the casing. 
            
            • Belt drive
            The belt-driven units are employed for   applications where the                     motor must be placed out of   the air stream. Generally, V-belt                     belts are used by   us as the connecting medium. 
            
              • Fan Performance
              The way Pasko fan impellers (blades or rotors)   are designed,                     the amount of air they can move   decreases as the pressure they                     are working against   increases. The airflow vs. pressure information                     for a   particular fan is called the fan performance data. The                       performance of a fan depends on the size, shape & speed                       of the impeller. The fan performance data is essential for   selecting                     fans as per the desired airflow and system   pressure.
              
              
• Fan Performance Curves
            Fan performance curves and data show how much   pressure and airflow                     a given fan can produce at a   given speed. This data is based                     on the system   resistance (pressure) occurring away from the                     fan.   Fan performance curves are developed by fan manufacturers                       based on the testing of a prototype fan fabricated based on                       the theoretical design.
          • Applications
            The Pasko axial flow fans are widely used for   providing the                     required airflow for heat & mass   transfer operations in                     various industrial equipment   and processes. These include cooling                     towers for   air-conditioning & ventilation, humidifiers in                       textile mills, air-heat exchangers for various chemical processes,                       ventilation & exhaust as in mining industry etc. All   the                     major industries use large number of axial flow   fans for operations,                     such as Power generation,   Petroleum refining & petrochemicals,                     Cement,   Chemicals & pharmaceuticals.
              
              • Product Description 
              
            Impeller diameter : 250 up to 1600 mm 
            Casing thickness : Up to 12 mm 
            Impeller types : Fixed / adjustable pitch 
            Motor frame size : 63 up to 280 
            Casing form : Short/Long casing/Bi furcated.
            Surface treatment : Primer, finish, hot-dip galvanized, on request
            Material :
            Impeller : Corrosion resistant cast aluminium 
            Casing : Steel, aluminium, special alloys 
            Special design : Flame-proof/ corrosion resistant/shock proof.
          • Standard Accessories 
          
            -  Inlet cone
 
            - Protection grill
 
            - Wall cowl
             
            - Feet for horizontal/vertical position
 
            - Vibration attenuator
 
            - Flexible connection
 
            - Counter flange
 
            - Silencer